Introduction
General Description
The Model 915 power control system is a complete power control “solution” featuring a number
of elements integrated into a single, ready-to-install package. The Model 915 is a single-phase
power control system available in a variety of configurations from 120 to 480 volts and rated at
20-, 40-, or 70-amps. These systems are ideally
suited for many industrial power control
applications and have been specifically
optimized for use with Research Inc. infrared
heating systems.
Standard Features
Standard features include:
Local 10 turn potentiometer with digital dial for precise manual control of load voltage.
Remote control capability with a 0-5 VDC or 0-20 mA signal.
Heater power switch with remote interlocks. The load voltage may be enabled or
disabled without turning off the main discount switch.
Heater ON/OFF switch controls an AC contactor to remove power from the SCR
controller and the load.
Cooling power switch to control air or water cooling flow.
Cooling flow interlock contacts. Low cooling flow turns off the heater contactor.
Heater over temperature contacts. Heater over temperature condition turns off the
heater contactor.
Indicators lights for heater on, cooling on, heater over temperature, optional
temperature controller alarm and lamp-out alarm.
Fail safe operation of the heater contactor. The contactor will not automatically re-
energize after a power failure, or an alarm condition that shuts down the heater.
Programmable Logic Controller for operating and alarm logic control.